What parameters affect SAR?

What parameters affect SAR?

Precautions to reduce the SAR to patients can include:

  • taking breaks between high SAR sequences.
  • alternating between low SAR and high SAR sequences.
  • reducing the flip angle.
  • reducing slice numbers.
  • reducing pulse number and duration.
  • reducing pulse frequency.
  • ensuring the patient is lightly dressed.

What affects MRI SAR?

Other critical factors include: regional perfusion, baseline patient body temperature, the patient’s thermoregulatory capacity, ambient temperature, airflow through the scanner bore, relative humidity, clothing, and ability to perspire.

What is the SAR limit in MRI?

According to the U.S. Food and Drug Administration, the average SAR values are limited to 3 W/kg when the head is scanned for 10 min and to 4 W/kg when the body is scanned for 15 min7. In addition, the local SAR levels averaged over 10 g of tissue also need to be restricted even though a higher level is allowed.

Which part of the MRI process mostly contributes to the SAR value?

SAR is proportional to the duty cycle (D). Duty cycle represents the percent time in a pulse sequence RF is being transmitted. Thus more intense sequences (with lots of RF pulses applied in a short period of time) generate high levels of SAR.

How can reduce SAR?

Precautions to reduce the SAR to patients can include:

  1. taking breaks between high SAR sequences.
  2. alternating between low SAR and high SAR sequences.
  3. reducing the flip angle.
  4. reducing slice numbers.
  5. reducing pulse number and duration.
  6. reducing pulse frequency.
  7. ensuring the patient is lightly dressed.

How is SAR value measured?

SAR is expressed in units of watts per kilogram (W/kg). The maximum SAR level for a mobile phone used against the head or body in accordance with the ICNIRP International guidelines is 2W/kg (using 10gm averaging mass).

Why is SAR important in MRI?

To help monitor heating of patient tissue, the MRI scanner estimates the SAR of each acquisition on the basis of the technical details of the scanning acquisition and patient weight. The SAR estimate is displayed on the scanner console before scanning is initiated.

Is an MRI a static magnetic field?

In a clinical setting, MRI scanners routinely use static magnetic fields in the range of 200–3000 mT. These fields are generated by permanent magnets, by the flow of direct current (DC) through superconductors , and by combinations of the two.

What does SAR value depend on?

The value will depend heavily on the geometry of the part of the body that is exposed to the RF energy, and on the exact location and geometry of the RF source. Thus tests must be made with each specific source, such as a mobile phone model, and at the intended position of use.

What level of SAR is safe?

1.6 W/Kg
The SAR value is the rate at which the body absorbs this lost electromagnetic waves. According to US Federal Communications Commission (FCC), phones with a SAR level of 1.6 W/Kg for body or below are deemed safe.

Which SAR value is safe?

According to US Federal Communications Commission (FCC), phones with a SAR level of 1.6 W/Kg for body or below are deemed safe. The same measurement is followed in India. In Europe, the government agencies require that the phone should have a SAR value of less than 2W/kg.

Is MRI an EMF?

The World Health Organisation (WHO) has classified both magnetic fields [1] and radiofrequency (RF) fields [2] as a possible carcinogenic to humans, “group 2B.” Magnetic resonance imaging (MRI) has a complex mixture of electromagnetic fields (EMFs), ranging from static, low-frequency, and RF magnetic fields [3].